Welcome to our websites!

Medical Treatment&non-Woven Fabric Testing Instruments

  • (China)YYP 506  Particulate Filtration Efficiency Tester

    (China)YYP 506 Particulate Filtration Efficiency Tester

    I.Instrument use:

    It is used to quickly, accurately and stably test the filtration efficiency and airflow resistance of various masks, respirators, flat materials, such as glass fiber, PTFE, PET, PP melt-blown composite materials.

     

    II. Meeting Standard:

     ASTM D2299—— Latex Ball Aerosol test

     

     

  • (China)YYP371  Medical Mask Gas Exchange Pressure Difference Tester

    (China)YYP371 Medical Mask Gas Exchange Pressure Difference Tester

    1. Applications:

    It is used to measure the gas exchange pressure difference of medical surgical masks and other products.

    II.Meeting Standard:

    EN14683:2019;

    YY 0469-2011 ——-medical surgical masks 5.7 pressure difference;

    YY/T 0969-2013—– disposable medical masks 5.6 ventilation resistance and other standards.

  • (China)YYT227B  Synthetic Blood Penetration Tester

    (China)YYT227B Synthetic Blood Penetration Tester

    Instrument use:

    The resistance of medical masks to synthetic blood penetration under different sample pressures can also be used to determine the blood penetration resistance of other coating materials.

     

    Meet the standard:

    YY 0469-2011;

    GB/T 19083-2010;

    YY/T 0691-2008;

    ISO 22609-2004

    ASTM F 1862-07 

  • (China)YY710  Gelbo Flex Tester

    (China)YY710 Gelbo Flex Tester

    I.Instrument Applications:

    For non-textile fabrics, non-woven fabrics, medical non-woven fabrics in the dry state of the amount

    of fiber scraps, raw materials and other textile materials can be dry drop test. The test sample is subjected to a combination of torsion and compression in the chamber. During this twisting process,

    air is extracted from the test chamber, and the particles in the air are counted and classified by a

    laser dust particle counter.

     

     

    II.Meet the standard:

    GB/T24218.10-2016,

    ISO 9073-10,

    INDA IST 160.1,

    DIN EN 13795-2,

    YY/T 0506.4,

     EN ISO 22612-2005,

    GBT 24218.10-2016 Textile nonwovens test methods Part 10 Determination of dry floc, etc.;

     

  • (China)YYT 258B Sweating Guarded Hotplate

    (China)YYT 258B Sweating Guarded Hotplate

    Instrument use:

    It is used to test the thermal resistance and wet resistance of textiles, clothing, bedding, etc., including multi-layer fabric combination.

    Meet the standard:

    GBT11048, ISO11092 (E), ASTM F1868, GB/T38473 and other standards.

  • (China)YY501B  Water Vapour Transmission Rate Tester

    (China)YY501B Water Vapour Transmission Rate Tester

    I.Instrument use:

    Used for measuring moisture permeability of medical protective clothing, various coated fabrics, composite fabrics, composite films and other materials.

     

    II.Meeting Standard:

    1.GB 19082-2009 –Medical disposable protective clothing technical requirements 5.4.2 moisture permeability;

    2.GB/T 12704-1991 —Method for determination of moisture permeability of fabrics – Moisture permeable cup method 6.1 Method A moisture absorption method;

    3.GB/T 12704.1-2009 –Textile fabrics – Test methods for moisture permeability – Part 1: moisture absorption method;

    4.GB/T 12704.2-2009 –Textile fabrics – Test methods for moisture permeability – Part 2: evaporation method;

    5.ISO2528-2017—Sheet materials-Determination of water vaport transmission rate (WVTR)–Gravimetric(dish)method

    6.ASTM E96; JIS L1099-2012 and other standards.

     

  • YYT-GC-7890  Ethylene Oxide, Epichlorohydrin Residue Detector

    YYT-GC-7890 Ethylene Oxide, Epichlorohydrin Residue Detector

    ①According to the provisions of GB15980-2009, the residual amount of ethylene oxide in disposable syringes, surgical gauze and other medical supplies should be no more than 10ug/g, which is considered as qualified. GC-7890 gas chromatograph is specially designed for the detection of residual amount of ethylene oxide and epichlorohydrin in medical instruments. ②GC-7890 gas chromatograph using microcomputer control system and large Chinese screen display, the appearance is more beautiful and sm...
  • (China)YY313B  Mask Tightness Tester

    (China)YY313B Mask Tightness Tester

    Instrument use:

    Particle tightness (suitability) test for determining masks;

     

    Standards compliant:

    GB19083-2010 technical requirements for medical protective masks Appendix B and other standards;

  • (China)YY461E   Automatic Air Permeability Tester

    (China)YY461E Automatic Air Permeability Tester

    Meeting Standard:

    GB/T5453、GB/T13764,ISO 9237、EN ISO 7231、AFNOR G07,ASTM D737,BS5636,DIN 53887,EDANA 140.1,JIS L1096,TAPPIT251.

  • (China)YY722  Wet Wipes Packing Tightness Tester

    (China)YY722 Wet Wipes Packing Tightness Tester

    It is suitable for the sealing test of bags, bottles, tubes, cans and boxes in food, pharmaceutical, medical equipment, daily chemical, automobile, electronic components, stationery and other industries. It can also be used to test the sealing performance of the sample after the drop and pressure test. GB/T 15171 ASTM D3078 1. Negative pressure method test principle 2. Provide standard, multi-stage vacuum, methylene blue and other test modes 3. Realize the automatic testing of traditional met...
  • YY721  Wipe Dust Tester

    YY721 Wipe Dust Tester

    Suitable for all kinds of paper, cardboard surface dust. GB/T1541-1989 1. light source: 20W fluorescent lamp 2. Irradiation Angle: 60 3. Rotating table: 270mmx270mm, effective area of 0.0625m2, can rotate 360 4. Standard dust picture: 0.05 ~ 5.0 (mm2) 5. Overall dimension :428×350×250 (mm) 6. Quality: 8KG
  • YY361A  Hydroscopicity Tester

    YY361A Hydroscopicity Tester

    Used for testing nonwoven fabrics in liquid, including water absorption time test, water absorption test, water absorption test. ISO 9073-6 1. The main part of the machine is 304 stainless steel and transparent plexiglass material. 2.In strict accordance with the standard requirements to ensure the accuracy and comparability of the test data. 3.Water absorption capacity test part height can be fine-tuned and equipped with a scale. 4. This set of instrument used sample clamps are made of 30...
12345 Next > >> Page 1 / 5