The DRK-LX dry Flocculation tester measures the amount of lint in the dry state of the nonwoven fabric according to the ISO 9073-10 method. The raw material nonwoven fabric and other textile materials can be subjected to dry flocculation experiments.
The sample was subjected to a combination of rotation and compression in the test chamber. Air is extracted from the test chamber during this distortion process, and particles in the air are counted and classified using a laser dust particle coun...
Used to measure the resistance to bacterial penetration in liquid when subjected to mechanical friction (the resistance to bacterial penetration in liquid when subjected to mechanical friction) of medical operation sheet, operating garment and clean clothing.
YY/T 0506.6-2009—Patients, medical staff and instruments – Surgical sheets, operating garments and clean clothing – Part 6: Test methods for the penetration of wet-resistant microorganisms
ISO 22610—Surgical drape...
The test system consists of a gas source generation system, a detection main body, a protection system, a control system, etc. It is used to conduct a dry microorganism penetration test method for surgical drapes, surgical gowns and clean clothes for patients, medical staff and instruments.
●Negative pressure experiment system, equipped with fan exhaust system and efficient air inlet and outlet filters to ensure the safety of operators;
●Industrial high-brightness color touch display screen;
...
This instrument is specially designed for testing the permeability of medical protective clothing against blood and other liquids; the hydrostatic pressure test method is used to test the penetration ability of protective clothing materials against viruses and blood and other liquids. Used to test the permeability of protective clothing to blood and body fluids, blood pathogens (tested with Phi-X 174 antibiotic), synthetic blood, etc. It can test the anti-liquid penetration performance of pro...
YYT1000 Bacterial Filtration Efficiency Detector not only conforms to the requirements of medical surgical masks technology YY0469-2011 appendix B in the test method for filter efficiency (BFE) bacteria first b. 1.1.1 test instrument, but also conforms to the American society for testing material ASTMF2100, ASTMF2101, the requirements of the European EN14683 standards, innovative improvements were made on the basis of this, with double pneumatic contrast sampling method at the same time, impr...
YYT822 automatic filter machine used for water solution sample membrane filtration method (1) microbial limit test (2) microbial contamination test, the test of pathogenic bacteria in sewage (3) asepsis test.
EN149
1.Built-in vacuum pump negative pressure suction filter, reduce the occupation of the operation platform space;
2. Color touch screen display, control, Chinese and English interface, menu operation mode.
3.The core control components are composed of multifunctional motherboard by...
A low-voltage bulb is installed at the eyeball position of the standard head shape, so that the stereoscopic surface of the light emitted by the bulb is equal to the stereoscopic angle of the average field of vision of Chinese adults. After wearing the mask, in addition, the light cone was reduced due to the limitation of the mask eye window, and the percentage of saved light cone was equivalent to the visual field preservation rate of standard head type wearing mask. The visual field map aft...
Touch color screen rubbing tester measurement and control instrument (hereinafter referred to as the measurement and control instrument) adopts the latest ARM embedded system, 800X480 large LCD touch control color display, amplifiers, A/D converters and other devices adopt the latest technology, with high precision and high The characteristics of resolution, analog microcomputer control interface, simple and convenient operation, greatly improve the test efficiency. Stable performance, comple...
The product is suitable for EN149 test standards: Respiratory protection device-filtered anti-particulate half-mask; Compliant with standards: BS EN149:2001+A1:2009 Respiratory protection device-filtered anti-particulate half-mask required test mark 8.10 blocking test,and EN143 7.13 standard test,etc,
Principle of blocking test: Filter and mask blocking tester are used to test the amount of dust collected on the filter when the airflow through the filter by way of inhalation in a certain dust...
1. Purpose:
The machine is suitable for repeated flexure resistance of coated fabrics, providing reference for improving fabrics.
2. Principle:
Place a rectangular coated fabric strip around two opposite cylinders so that the specimen is cylindrical. One of the cylinders reciprocates along its axis, causing alternating compression and relaxation of the coated fabric cylinder, causing folding on the specimen. This folding of the coated fabric cylinder lasts until a predetermined number of cycl...
It is used to test the ability of medical protective clothing materials and non-woven fabrics to eliminate the charge induced to the surface of the material when the material is earthed, that is, to measure the electrostatic decay time from the peak voltage to 10%.
GB 19082-2009
1. Large screen color touch screen display, Chinese and English interface, menu operation mode.
2. The whole instrument adopts four-part module design:
2.1 ±5000V voltage control module;
2.2. High-voltage discharge m...
The impact permeability tester is used to measure the water resistance of fabric under low impact condition, so as to predict the rain permeability of fabric.
AATCC42 ISO18695
Model No.:
DRK308A
Impact Height:
(610±10)mm
Diameter of the funnel:
152mm
Nozzle Qty:
25 pcs
Nozzle aperture:
0.99mm
Sample Size:
(178±10)mm×(330±10)mm
Tension spring clamp:
(0.45±0.05)kg
Dimension:
50×60×85cm
Weight:
10Kg