Welcome to our websites!

Medical Treatment&non-Woven Fabric Testing Instruments

  • YYT-07B  Respirator Flame Retardant Tester

    YYT-07B Respirator Flame Retardant Tester

    The flame retardant tester for respirator is developed according to gb2626 respiratory protective equipment, which is used to test the fire resistance and flame retardant performance of respirators. The applicable standards are: gb2626 respiratory protective articles, gb19082 technical requirements for disposable medical protective clothing, gb19083 technical requirements for medical protective masks, and gb32610 technical specification for daily protective masks Yy0469 medical surgical mask,...
  • YYT-07A Fabric Flame Retardant Tester

    YYT-07A Fabric Flame Retardant Tester

    1. Ambient temperature: – 10 ℃~ 30 ℃ 2. Relative humidity: ≤ 85% 3. Power supply voltage and power: 220 V ± 10% 50 Hz, power less than 100 W 4. Touch screen display / control, touch screen related parameters: a. Size: 7 “effective display size: 15.5cm long and 8.6cm wide; b. Resolution: 480 * 480 c. Communication interface: RS232, 3.3V CMOS or TTL, serial port mode d. Storage capacity: 1g e. Using pure hardware FPGA drive display, “zero” start-up time, power on can ru...
  • YY6001A Protective Clothing Cutting Ability Tester (against sharp objects)

    YY6001A Protective Clothing Cutting Ability Tester (against sharp objects)

    Used for testing the performance of materials and components in the design of protective clothing. The amount of vertical (normal) force required to cut through the test specimen by cutting the blade over a fixed distance. EN ISO 13997 1. Color touch screen display, control, Chinese and English interface, menu operation mode; 2.Servo motor drive, high precision ball screw control speed; 3. Imported high precision bearings, small friction, high precision; 4. No radial swing, no runout and v...
  • YYT-T453 Protective Clothing Anti-Acid And Alkali Test System

    YYT-T453 Protective Clothing Anti-Acid And Alkali Test System

    The conductivity method and automatic timing device are used to test the penetration time of the fabric protective clothing for acid and alkali chemicals. The sample is placed between the upper and lower electrode sheets, and the conductive wire is connected to the upper electrode sheet and is in contact with the upper surface of the sample. When the penetrating phenomenon occurs, the circuit is turned on and the timing stops. The instrument structure mainly includes the following parts: 1. U...
  • YYT-T453 Protective clothing anti-acid and alkali test system

    YYT-T453 Protective clothing anti-acid and alkali test system

    This instrument is specially designed to measure the liquid repellent efficiency of fabric protective clothing fabrics for acid and alkali chemicals. 1. Semi-cylindrical plexiglass transparent tank, with an inner diameter of (125±5) mm and a length of 300 mm. 2. The diameter of the injection needle hole is 0.8mm; the needle tip is flat. 3. Automatic injection system, continuous injection of 10mL reagent within 10s. 4. Automatic timing and alarm system; LED display test time, accuracy 0.1S. 5....
  • YYT-T453 Protective Clothing Acid And Alkali Resistance Test System Operation Manual

    YYT-T453 Protective Clothing Acid And Alkali Resistance Test System Operation Manual

    This instrument is used to test the hydrostatic pressure resistance of fabric protective clothing for acid and alkali chemicals. The hydrostatic pressure value of the fabric is used to express the resistance of the reagent through the fabric. 1. Liquid adding barrel 2. Sample clamp device 3. Liquid drain needle valve 4. Waste liquid recovery beaker Appendix E of “GB 24540-2009 Protective Clothing Acid-base Chemical Protective Clothing” 1. Test accuracy: 1Pa 2. Test range: ...
  • (China)YY378 -Dolomite Dust Clogging

    (China)YY378 -Dolomite Dust Clogging

    The product is applicable to EN149 test standard: respiratory protective device-filtered anti-particle semi-mask; Conforming standards: BS EN149:2001+A1:2009 Respiratory protective device-filtered anti-particle semi-mask requirements test mark 8.10 blocking test, EN143 7.13 and other test standards.

     

    Blocking test principle: the filter and mask blocking tester is used to test the amount of dust collected on the filter, the respiratory resistance of the test sample and the filter penetration (permeability) when the air flow passes through the filter by suction in a certain dust environment and reaches a certain respiratory resistance.