[Scope of application]
Used for the stiffness determination of cotton, wool, silk, hemp, chemical fiber and other kinds of woven fabric, knitted fabric and general non-woven fabric, coated fabric and other textiles, but also suitable for the stiffness determination of paper, leather, film and other flexible materials.
[Related standards]
GB/T18318.1, ASTM D 1388, IS09073-7, BS EN22313
【 Instrument characteristics 】
1.Infrared photoelectric invisible incline detection system, instead of the traditional tangible incline, to achieve non-contact detection, overcome the problem of measurement accuracy due to the sample torsion is held up by the incline;
2. Instrument measurement angle adjustable mechanism, to adapt to different test requirements;
3. Stepper motor drive, accurate measurement, smooth operation;
4. Color touch screen display, can display the specimen extension length, bending length, bending stiffness and the above values of meridian average, latitude average and total average;
5. Thermal printer Chinese report printing.
【 Technical parameters 】
1. Test method: 2
(A method: latitude and longitude test, B method: positive and negative test)
2. Measuring Angle: 41.5°, 43°, 45° three adjustable
3.Extended length range: (5-220)mm (special requirements can be put forward when ordering)
4. Length resolution: 0.01mm
5.Measuring precision: ±0.1mm
6. Test sample gauge 250×25)mm
7. Working platform specifications 250×50)mm
8. Sample pressure plate specification 250×25)mm
9.Pressing plate propulsion speed: 3mm/s; 4mm/s; 5mm/s
10.Display output: touch screen display
11.Print out: Chinese statements
12. Data processing capacity: a total of 15 groups, each group ≤20 tests
13.Printing machine: thermal printer
14. Power source: AC220V±10% 50Hz
15. Main machine volume: 570mm×360mm×490mm
16. Main machine weight: 20kg
[Scope of application]
Used for all kinds of zipper load fatigue performance test.
[Related standards]
QB/T2171 QB/T2172 QB/T2173, etc
【 Technical parameters 】 :
1.Reciprocating stroke: 75mm
2. Transverse clamping device width: 25mm
3. Total weight of longitudinal clamping device 0.28 ~ 0.34)kg
4. The distance between the two clamping devices: 6.35mm
5. Opening Angle of specimen: 60°
6. Meshing Angle of specimen: 30°
7.Counter: 0 ~ 999999
8. Power supply :AC220V±10% 50Hz 80W
9.Dimensions (280×550×660)mm (L×W×H)
10. The weight is about 35kg
[Scope] :
Used for testing the pilling performance of fabric under free rolling friction in drum.
[Relevant standards] :
GB/T4802.4 (Standard drafting unit)
ISO12945.3, ASTM D3512, ASTM D1375, DIN 53867, ISO 12945-3, JIS L1076, etc
【 Technical parameters 】 :
1. Box quantity: 4 PCS
2. Drum specifications: φ 146mm×152mm
3.Cork lining specification 452×146×1.5) mm
4. Impeller specifications: φ 12.7mm×120.6mm
5. Plastic blade specification: 10mm×65mm
6.Speed 1-2400)r/min
7. Test pressure 14-21)kPa
8.Power source: AC220V±10% 50Hz 750W
9. Dimensions :(480×400×680)mm
10. Weight: 40kg
[Scope of application] :
It is used for testing gram weight, yarn count, percentage, particle number of textile, chemical, paper and other industries.
[Related standards] :
GB/T4743 “yarn linear density determination Hank method”
ISO2060.2 “Textiles – Determination of yarn linear density – Skein method”
ASTM, JB5374, GB/T4669/4802.1, ISO23801, etc
[Instrument characteristics] :
1. Using high precision digital sensor and single chip microcomputer program control;
2. With tare removal, self-calibration, memory, counting, fault display and other functions;
3. Equipped with special wind cover and calibration weight;
[Technical parameters] :
1. Maximum weight :200g
2. Minimum degree value :10mg
3. Verification value :100mg
4. Accuracy level: III
5. Power supply :AC220V±10% 50Hz 3W
[Scope of application]
Used for testing the breaking strength and elongation of single yarn and pure or blended yarn of cotton, wool, hemp, silk, chemical fiber and core-spun yarn.
[Related standards]
GB/T14344 GB/T3916 ISO2062 ASTM D2256
[Scope of application]
Used for testing the breaking strength and elongation of single yarn and pure or blended yarn of cotton, wool, hemp, silk, chemical fiber and core-spun yarn.
[Related standards]
GB/T14344 GB/T3916 ISO2062 ASTM D2256
[Scope of application] Used for testing the breaking strength and elongation of single yarn and pure or blended yarn of cotton, wool, hemp, silk, chemical fiber and core-spun yarn.
[Related standards] GB/T14344 GB/T3916 ISO2062 ASTM D2256
【 Scope of application 】
Ultraviolet lamp is used to simulate the effect of sunlight, condensation moisture is used to simulate rain and dew, and the material to be measured is placed at a certain temperature
The degree of light and moisture are tested in alternating cycles.
【 Relevant standards 】
GB/T23987-2009, ISO 11507:2007, GB/T14522-2008, GB/T16422.3-2014, ISO4892-3:2006, ASTM G154-2006, ASTM G153, GB/T9535-2006, IEC 61215:2005.
Test the color fastness of fabrics when exposed to nitrogen oxides produced by gas combustion.
[Scope of application] :
Used for tumbling drying of fabric, clothing or other textiles after shrinkage test.
[Related standards] :
GB/T8629, ISO6330, etc
[Scope] :
Used for tumble drying of fabric, garment or other textile after shrinkage test.
[Relevant standards] :
GB/T8629 ISO6330, etc
(Floor tumble drying, YY089 matching)
[Scope of application]
Used for determination of moisture regain (or moisture content) of various fibers, yarns and textiles and other constant temperature drying.
[Related standards] GB/T 9995 ISO 6741.1 ISO 2060, etc.
[Scope of application]
Used for determination of moisture regain (or moisture content) of various fibers, yarns, textiles and constant temperature drying in other industries.
[Test principle]
According to the preset program for rapid drying, automatic weighing at a certain time interval, the comparison of the two weighing results, when the weight difference between two adjacent times is less than the specified value, that is, the test is completed, and automatically calculate the results.
[Relevant standards]
GB/T 9995-1997, GB 6102.1, GB/T 4743, GB/T 6503-2008, ISO 6741.1:1989, ISO 2060:1994, ASTM D2654, etc.
Instrument Introduction:
The heat shrink tester is suitable for testing the heat shrink performance of materials, which can be used for plastic film substrate (PVC film, POF film, PE film, PET film, OPS film and other heat shrink films), flexible packaging composite film, PVC polyvinyl chloride hard sheet, solar cell backplane and other materials with heat shrink performance.
Instrument characteristics:
1. Microcomputer control, PVC menu type operation interface
2. Humanized design, easy and fast operation
3. High-precision circuit processing technology, accurate and reliable test
4. Liquid non-volatile medium heating, heating range is wide
5. Digital P.I.D temperature control monitoring technology can not only quickly reach the set temperature, but also effectively avoid temperature fluctuations
6. Automatic timing function to ensure test accuracy
7. Equipped with standard sample holding film grid to ensure that the sample is stable without interference from temperature
8. Compact structure design, light and easy to carry
Instrument use:
It can accurately and quantitatively measure the thermal shrinkage force, cold shrinkage force, and thermal shrinkage rate of plastic film in the process of thermal shrinkage. It is suitable for the accurate determination of thermal shrinkage force and thermal shrinkage rate above 0.01N.
Meet the standard:
GB/T34848,
IS0-14616-1997,
DIN53369-1976
I.Instrument use:
It is used to quickly, accurately and stably test the filtration efficiency and airflow resistance of various masks, respirators, flat materials, such as glass fiber, PTFE, PET, PP melt-blown composite materials.
II. Meeting Standard:
ASTM D2299—— Latex Ball Aerosol test
It is used to measure the gas exchange pressure difference of medical surgical masks and other products.
II.Meeting Standard:
EN14683:2019;
YY 0469-2011 ——-medical surgical masks 5.7 pressure difference;
YY/T 0969-2013—– disposable medical masks 5.6 ventilation resistance and other standards.
Instrument use:
The resistance of medical masks to synthetic blood penetration under different sample pressures can also be used to determine the blood penetration resistance of other coating materials.
Meet the standard:
YY 0469-2011;
GB/T 19083-2010;
YY/T 0691-2008;
ISO 22609-2004
ASTM F 1862-07
Ink Mixer Introduction:
In order to meet the market demand and meet the higher requirements of customers, the company
has designed and produced a new generation of YYP2000-D mixer. Simple and convenient operation;
Low speed, intermittent agitation on the side of the barrel; Unique mixing paddle design, the ink can be turned and cut during the mixing process, and the ink can be thoroughly mixed within ten minutes; The stirred ink does not heat up. Convenient refuelling bucket, (stainless steel bucket); Mixing speed can be regulated by frequency conversion.
Technology Parameter
Single phase three lines 220VAC ~ 50Hz |
|||
OVERALL POWER |
2.2KW |
GROSS WEIGHT |
100kg |
EXTERIOR SIZE |
1250L*540W*1100H |
ENTER SIZE |
50-100mm |
CONVEYOR BELT |
STAINLESS STEEL BELT |
CONVEYOR BELT SPEED |
1-10m/min |
UV LAMP |
HIGH PRESSURE MERCURY LAMP |
CONVEYOR BELT WIDTH |
300mm |
COOLING MANNER |
AIR COOLING |
|
2KW*1PC |