Determining oxygen permeability characteristics of materials and container.
Suitable for: Film, sheet, container and construction material of plastic, textile, leather and metal.
Coulemeter Sensor method
Dry oxygen(or with a certain humidity)flows on one side of the specimen, and high-purity nitrogen (carrier gas) flows at a fixed flow rate on the other side; The oxygen concentration difference between the two sides of the specimen drives the oxygen to penetrate from the oxygen side of the specimen to the nitrogen side; The permeated oxygen is carried to the coulometer sensor by nitrogen (carrier gas); The sensor measures the oxygen content of carrier gas and calculates the oxygen permeability of the specimen.
YBB 00082003、GB/T 19789、ASTM D3985、ASTM F2622、ASTM F1307、ASTM F1927、ISO 15105-2、JIS K7126-B
Original imported oxygen sensor, ppb accuracy.
Humidity control ability: 35%~95%RH, 100%RH, fully automatic, fogless.
Temperature control feature: Semiconductor cold and hot bidirectional control, High precision, stable and reliable.
Strong environmental adaptability: Indoor environment, temperature 10 ℃ – 30 ℃, any humidity, low cost of use.
specimen side leakage proof sealing installation technology.
Intelligent and automatic: power-on self-test to avoid test under fault state; one key start, fully automatic test execution.
Software: graphical, whole process and all element monitoring; multiple report formats.
Optional: software module of GMP computerization system.
Name |
Parameter |
Name |
Parameter |
|
Humidity Range |
0% RH,35%~95%RH,100%RH |
Humidity Error |
±1%RH |
|
Temperature Range |
15℃~50℃ |
Temperature Error |
±0.1℃ |
|
Specimen Thickness |
<3 mm |
Gas pressure |
≥0.2 MPa |
|
Carrier gas |
99.999% purity nitrogen |
Carrier gas flow |
0~100 cm3/min |
|
Interface size |
1/8-inch mental pipe |
Size (L×B×H) mm |
720(L)×415(W)×400(H) |
|
Power Supply |
AC 220V 50Hz |
Power consumption |
1200W |
|
Model special |
Model |
|||
|
YY310–11-A |
YY310—31-M |
YY310—41-E |
|
Specimen Count |
1 |
3 |
4 |
|
Test Area(cm2) |
50 |
7 |
50 |
|
Film Measure Range (cm3/m2.24h) |
0.01~14,000 |
0.05~70,000 |
0.01~14,000 |
|
Film Measure Error (cm3/m2.24h) |
0.01 |
0.05 |
0.01 |
|
Package Measure Range (cm3/pkg.24h) |
0.00005~70 |
/ |
0.00005~70 |
|
Package Measure Error (cm3/m2.24h) |
0.00005 |
/ |
0.00005 |
|
Net Weight (kg) |
52 |
73 |
82 |
Configuration: Main engine, test computer, professional test software, Agilent oxygen trap, specimen sampler, 2 pressure reducing valves, sealing grease.
Optional: software module of GMP computerization system, container test component, container temperature control test component.
Self-Supply: High purity Oxygen, High purity nitrogen, distilled water.