Product features:
1. Adopt high-precision imported brand differential pressure transmitter to ensure the accuracy and stability of the air resistance differential pressure of the tested sample.
2. The use of well-known brands of high-precision double photometer sensor, while monitoring the upstream and downstream particle concentration mg/m3, to ensure accurate, stable, fast and effective sampling.
3. The test inlet and outlet air is equipped with a cleaning device to ensure that the test air is clean and the exclusion air is clean, and the test environment is pollution-free.
4. The use of frequency control mainstream fan speed automatic control test flow and stable within the set flow rate of ±0.5L/min.
5. Collision multi-nozzle design is adopted to ensure rapid and stable adjustment of fog concentration. Dust particle size meets the following requirements:
5.1 Saltiness: The concentration of NaCl particles is 1mg/m3 ~ 25mg/m3, the median diameter of counting is (0.075±0.020) μm, and the geometric standard deviation of particle size distribution is less than 1.86.
5.2. 0il: oil particle concentration 10 ~ 200mg/m3, the counting median diameter is (0.185±0.020) μm, the geometric standard deviation of particle size distribution is less than 1.6.
6. with 10-inch touch screen, Omron PLC controller. Test results are displayed or printed directly. Test results include test reports and loading reports.
7. The whole machine operation is simple, just place the sample between the fixture, and press the two start keys of the anti-pinch hand device at the same time. There is no need to do a blank test.
8. The machine noise is less than 65dB.
9. Built-in automatic calibration particle concentration program, just input the actual test load weight into the instrument, the instrument automatically completes automatic calibration according to the set load.
10. The instrument built-in sensor automatic purification function, the instrument automatically enters the sensor automatic cleaning after the test, to ensure the zero consistency of the sensor.
11. Equipped with KF94 fast loading test function.
Technical parameters:
1. Sensor configuration: double photometer sensor
2. The number of fixture stations: double stations
3. Aerosol generator: salt and oil
4. Test mode: fast and loaded
5. Test flow range: 10L/min ~ 100L/min, accuracy 2%
6. Filtration efficiency test range: 0 ~ 99.999%, resolution 0.001%
7. The cross-sectional area of the air flow is: 100 cm2
8. Resistance test range: 0 ~ 1000Pa, accuracy up to 0.1Pa
9. Electrostatic neutralizer: equipped with electrostatic neutralizer, which can neutralize the charge of the particles.
10. Power supply, power: AC220V,50Hz,1KW
11. Overall dimension mm (L×W×H) : 800×600×1650
12. Weight :140kg
Configuration list:
3. Dust tank–1 pcs
4. Liquid collecting tank–1 pcs
5. One bottle of sodium chloride or DEHS
6. One calibration sample
Optional accessories:
1. Air pump 0.35 ~ 0.8MP; 100L/min
2. Fixture surface mask
3.Fixture N95 mask
4. Salt aerosol Nacl
5. Oil aerosol 500ml