Specification

Name

Parameter

Name

Parameter

Humidity Range

0% RH35%~95%RH100%RH

Humidity Error

±1%RH

Temperature Range

15℃50

Temperature Error

±0.1℃

Specimen Thickness

<3 mm

Gas pressure

≥0.2 MPa

Carrier gas

99.999% purity nitrogen

Carrier gas flow

0~100 cm3/min

Interface size

1/8-inch mental pipe

Size (L×B×H) mm

720(L)×415(W)×400(H)

Power Supply

AC 220V 50Hz

Power consumption

1200W

Model special

Model

YY310--11-A

YY310–-31-M

YY310–-41-E

Specimen Count

1

3

4

Test Area(cm2)

50

7

50

Film Measure Range

cm3/m2.24h

0.01~14,000

0.05~70,000

0.01~14,000

Film Measure Error

cm3/m2.24h

0.01

0.05

0.01

Package Measure Range

cm3/pkg.24h

0.00005~70

/

0.00005~70

Package Measure Error

(cm3/m2.24h)

0.00005

/

0.00005

Net Weight (kg)

 52

73

82


Product Detail

Product Tags

Function

Determining oxygen permeability characteristics of materials and container.

Suitable for: Film, sheet, container and construction material of plastic, textile, leather and metal.

Principle:

Coulemeter Sensor method

Dry oxygen(or with a certain humidity)flows on one side of the specimen, and high-purity nitrogen (carrier gas) flows at a fixed flow rate on the other side; The oxygen concentration difference between the two sides of the specimen drives the oxygen to penetrate from the oxygen side of the specimen to the nitrogen side; The permeated oxygen is carried to the coulometer sensor by nitrogen (carrier gas); The sensor measures the oxygen content of carrier gas and calculates the oxygen permeability of the specimen.

(~O5}]4MURXHS)XRLQ95R2M

Standards

YBB 00082003、GB/T 19789、ASTM D3985、ASTM F2622、ASTM F1307、ASTM F1927、ISO 15105-2、JIS K7126-B

Characteristics

Original imported oxygen sensor, ppb accuracy.
Humidity control ability: 35%~95%RH, 100%RH, fully automatic, fogless.
Temperature control feature: Semiconductor cold and hot bidirectional control, High precision, stable and reliable.
Strong environmental adaptability: Indoor environment, temperature 10 ℃ - 30 ℃, any humidity, low cost of use.
specimen side leakage proof sealing installation technology.
Intelligent and automatic: power-on self-test to avoid test under fault state; one key start, fully automatic test execution.
Software: graphical, whole process and all element monitoring; multiple report formats.
Optional: software module of GMP computerization system.

Specification

Name

Parameter

Name

Parameter

Humidity Range

0% RH,35%~95%RH,100%RH

Humidity Error

±1%RH

Temperature Range

15℃~50℃

Temperature Error

±0.1℃

Specimen Thickness

<3 mm

Gas pressure

≥0.2 MPa

Carrier gas

99.999% purity nitrogen

Carrier gas flow

0~100 cm3/min

Interface size

1/8-inch mental pipe

Size (L×B×H) mm

720(L)×415(W)×400(H)

Power Supply

AC 220V 50Hz

Power consumption

1200W

Model special

Model

 

YY310--11-A

YY310---31-M

YY310---41-E

Specimen Count

1

3

4

Test Area(cm2)

50

7

50

Film Measure Range

(cm3/m2.24h)

0.01~14,000

0.05~70,000

0.01~14,000

Film Measure Error

(cm3/m2.24h)

0.01

0.05

0.01

Package Measure Range

(cm3/pkg.24h)

0.00005~70

/

0.00005~70

Package Measure Error

(cm3/m2.24h)

0.00005

/

0.00005

Net Weight (kg)

 52

73

82

 

Configuration: Main engine, test computer, professional test software, Agilent oxygen trap, specimen sampler, 2 pressure reducing valves, sealing grease.

Optional: software module of GMP computerization system, container test component, container temperature control test component.

Self-Supply: High purity Oxygen, High purity nitrogen, distilled water.

puiada (2)

-----YY310-11-A/31-M

puiada (3)

-----YY310---41-E


  • Previous:
  • Next:

  • Write your message here and send it to us