Test the point to point resistance of the fabric.
GB 12014-2009
1.Adopt 3 1/2 digit digital display, bridge measuring circuit, high measuring accuracy, convenient and accurate reading.
2. Portable structure, small size, light weight, easy to use
3. Can be powered by battery, the instrument can work in the ground suspension state, not only improve the anti-interference ability and remove the power cord care, can also be used in fixed occasions external voltage regulator power supply.
4. Built-in timer, automatic reading lock, convenient test
5.Resistance measurement range up to 0 ~ 2×1013Ω, is the current point to point resistance measurement ability is strong digital instrument. It is the best instrument for measuring the volume resistivity and surface resistivity of insulating materials. The highest resolution is 100Ω.
6. 4 kinds of (10,50,100,500) output voltage, suitable for all kinds of clothing materials resistance test.
7. The built-in high-performance rechargeable battery, avoid the trouble of replacing the battery, save the cost of replacing the battery.
8. Humanized operation interface. Large screen, high brightness LCD screen, in addition to the measurement results display, there are measurement function display, output voltage display, measurement unit display, multiplier square display, battery low voltage alarm display, misoperation alarm display, all information at a glance.
1. Resistance measurement: 0 ~ 2×1013 (Ω)
2. Display: 31/2-digit large screen with backlight digital display
3. Measurement timing: 1min ~ 7min
4. Basic error of resistance measurement:
5. Resolution: instrument display in each range can be stable read out the minimum value of the corresponding resistance value should be less than or equal to the range allowable error of 1/10.
6. The end button voltage error: the instrument's end button voltage error is not more than ± 3% of the rated value
7. The end button voltage ripple content: the root mean square value of the instrument end button voltage ripple content is not greater than 0.3% of the DC component.
8. Measurement timing error: the measurement timing error of the instrument is not more than ±5% of the set value.
9. Power consumption: the built-in battery can work continuously for 30 hours. Power consumption of external power supply is less than 60mA.
10. Power supply: rated voltage (V) : DC 10, 50, 100, 500
Power supply: DC battery power 8.5 ~ 12.5V
Measuring voltage 100V, 500V |
measuring voltage 10V, 50V |
||
Measuring range |
intrinsic error |
Measuring range |
intrinsic error |
0~109Ω |
±( 1 % RX+ 2 字) |
0~108Ω |
±( 1 % RX+ 2 character) |
>109~1010Ω |
±( 2 % RX+ 2 字) |
>108~109Ω |
±( 2 % RX+ 2 character) |
>1010~1012Ω |
±( 3 % RX+ 2 字) |
>109~1011Ω |
±( 3 % RX+ 2 character) |
>1012~1013Ω |
±( 5 % RX+3 字) |
>1011~1012Ω |
±( 5 % RX+3 character) |
>1012~1013Ω |
±( 10 % RX+5 character) |
||
>1013Ω |
±( 20 % RX+ 10 character) |
AC power supply: AC 220V 50HZ 60mA