Technical Parameters:
Model |
YYP643A |
YYP643B |
YYP643C |
YYP643D |
YYP 643E |
Test chamber size(mm)W*D*H |
600x450x400 |
900x600x500 |
1200x800x500 |
1600x1000x500 |
2000x1200x600 |
Outside Chamber Size (mm)W*D*H |
1070x600x1180 |
1410x880x1280 |
1900x1100x1400 |
2300x1300x1400 |
2700x1500x1500 |
Laboratory temperature |
Brine test (NSS ACSS)35℃±1℃/ corrosion resistance test method (CASS)50℃±1℃ |
||||
Pressure tank temperature |
Brine test (NSS ACSS)47℃±1℃/ Corrosion resistance test(CASS)63℃±1℃ |
||||
Brine temperature |
35℃±1℃ 50℃±1℃ |
||||
Laboratory capacity |
108L |
270L |
480L |
800L |
1440L |
Brine tank capacity |
15L |
25L |
40L |
40L |
40L |
Brine concentration |
Add 0.26 g of copper chloride per liter in 5% sodium chloride solution or 5% sodium chloride solution (CuCl2 2H2O) |
||||
Compressed air pressure |
1.00±0.01kgf/cm2 |
||||
Spray Quantity |
1.0~2.0ml/80cm2/h ( Collect at least 16 hours, take the average ) |
||||
Relative Humidity |
85% or Above |
||||
PH value |
6.5~7.2 3.0~3.2 |
||||
Spray mode |
Continuous spray |
||||
Power Supply |
AC220V1Φ10A |
AC220V1Φ15A |
AC220V1Φ20A |
AC220V1Φ20A |
AC220V1Φ30A |